Alarm work covers three related devices that people tend to lump together. Smoke alarms detect the products of a fire and are the ones that go on ceilings in halls and landings. Heat alarms respond to a rise in temperature instead, which is why they belong in kitchens where cooking would set a smoke alarm off constantly. Carbon monoxide alarms detect something entirely different: a poisonous gas produced by appliances that burn fuel, whether or not anything is on fire.

Tell us about your smoke and CO detector project and we’ll help you find local electricians who serve your area.

Free for homeowners · No obligation to hire

This type of work often has to be done by a licensed or certified trade. Ask to see licences and proof of insurance before work starts.
On this page

The legal picture is genuinely different in each part of the United Kingdom, and this is one of the places where borrowing advice from the wrong nation gets people into trouble. England regulates alarms in rented homes through the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 as amended. Scotland sets a standard that applies to every home and makes it the property owner's responsibility. Northern Ireland legislates separately again, most recently through the Private Tenancies Act (Northern Ireland) 2022.

The installation question that follows is whether alarms should be mains-wired and interlinked or sealed-battery and radio-linked. Both routes exist, both can meet the relevant standard, and the choice usually comes down to the building, the wiring and how much disruption you are willing to accept. Interlinking, so that one alarm sounding sets them all off, is the feature that matters most and the one homeowners most often leave out.

Smoke alarms, heat alarms and carbon monoxide alarms: what goes where

  • Smoke alarms: the primary fire detection device, normally ceiling-mounted in circulation spaces such as halls and landings, and on each storey used as living accommodation.
  • Heat alarms: used in kitchens, where cooking fumes would cause constant false alarms from a smoke alarm; Scotland's standard requires one heat alarm in the kitchen.
  • Carbon monoxide alarms: detect the gas rather than fire, and belong in rooms containing an appliance that burns fuel.
  • Mains-wired alarms with battery backup: hard-wired and typically interlinked by cable, which suits new work, rewires and refurbishments.
  • Sealed long-life battery alarms: no wiring, and commonly interlinked by radio, which suits existing homes where chasing cables would mean significant making good.
  • Interlinking: the feature that makes a group of alarms behave as one system, so an alarm in the kitchen wakes someone in a bedroom at the other end of the house.
  • Alarms designed for deaf and hard of hearing occupants, which use vibration and visual signals rather than sound alone.
  • Standards to ask for: government guidance for landlords in England points to British Standard BS 5839-6 for smoke alarms and BS 50291 for carbon monoxide alarms.

The law in England, Scotland and Northern Ireland, and who it binds

England's rules are aimed at landlords. Regulation 4 of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 requires a relevant landlord, during any period when the premises are occupied under the tenancy, to ensure that a smoke alarm is equipped on each storey of the premises on which there is a room used wholly or partly as living accommodation, and that a carbon monoxide alarm is equipped in any room of the premises which is used wholly or partly as living accommodation and contains a fixed combustion appliance other than a gas cooker. It also requires checks to be made to ensure each alarm is in proper working order on the day the tenancy begins if it is a new tenancy, and that an alarm reported as faulty on or after 1st October 2022 is repaired or replaced, as soon as reasonably practicable. The regulation treats a bathroom or lavatory as a room used as living accommodation, and says that room includes a hall or landing.

The gas cooker exclusion is the detail that catches people out, and it cuts the other way from what most people assume: a carbon monoxide alarm is required in a room with a fixed combustion appliance, and only the gas cooker is carved out. A gas fire, a gas boiler, an oil boiler, a wood burner, a solid fuel stove or an open fire in a room used as living accommodation all bring the requirement with them. Government guidance for landlords confirms the amended requirements came into force on 1 October 2022 and apply to all homes rented by private landlords or registered providers of social housing, unless excluded. Enforcement has teeth: under regulation 8 of the 2015 Regulations, the penalty charge a local housing authority may impose must not exceed £5,000.

Scotland goes further and applies to everyone. The Scottish Government's standard is that a home needs one smoke alarm in the living room or the room you use most, one smoke alarm in every hallway and landing, and one heat alarm in the kitchen, and that all smoke and heat alarms should be attached to the ceiling and be interlinked, so that if one goes off they all go off. On carbon monoxide it says that if you have a carbon-fuelled appliance like a boiler, open fire or wood burner, you must also have a carbon monoxide detector in the same room, while gas cookers and hobs do not need one. It is the property owner's responsibility for meeting the standard. That standard sits alongside the tolerable standard in section 86 of the Housing (Scotland) Act 1987, under which a house must have satisfactory equipment installed for detecting, and for giving warning of, fire or suspected fire, and satisfactory equipment installed for detecting, and for giving warning of, carbon monoxide present in a concentration that is hazardous to health. Northern Ireland is separate again: section 8 of the Private Tenancies Act (Northern Ireland) 2022 provides that the landlord under a private tenancy must keep in repair and in proper working order sufficient appliances for detecting fire or smoke, and gives the Department power to set minimum standards by regulations.

Where alarms go, and how an installation is planned

Positioning is not guesswork, and the Scottish Government's guidance gives usable figures: alarms should be ceiling mounted and at least 300 mm from any wall, unless otherwise indicated by the manufacturer, or wall mounted and positioned at least 150 mm below the ceiling and higher than any door or window. Government guidance for landlords in England adds that smoke alarms should be fixed to the ceiling in a circulation space, meaning a hall or a landing. Manufacturer instructions sit on top of all of that and are part of the job, not an optional extra.

Coverage comes before hardware. Walk the house as if you were leaving it in the dark: every storey used as living accommodation, every hall and landing, the kitchen with a heat alarm rather than a smoke alarm, and every room containing an appliance that burns fuel. Then decide on interlinking, because a group of alarms that cannot hear each other is a much weaker system in a two or three storey house, which describes a great deal of British stock.

Only then does the wiring question arise. Mains-wired interlinked alarms are the natural choice during a rewire, an extension or a refurbishment, when cables can be run without destroying finishes; retrofitting them into an occupied house means cable routes, chased walls or lifted floors and making good afterwards. Sealed-battery alarms interlinked by radio avoid all of that, which is why they dominate retrofit work. One British-specific warning: where a ceiling has a textured coating in a home built or refurbished before 2000, raise it before anyone drills, because the Scottish guidance itself notes that on such ceilings battery operated alarms can be attached using a firm adhesive rather than by drilling.

LokalMatch does the introduction and stops there. You describe the property, how many storeys it has, which rooms contain fuel-burning appliances, and whether you want mains-wired or battery alarms, once, with your postcode, and electricians covering your area get in touch. The pros pay for the requests they receive, and LokalMatch does not fit alarms, does not set prices and does not vet, rank or recommend anybody who replies, so it is worth asking each of them exactly how many alarms they are quoting for and whether they will be interlinked.

Which standards to ask for, and why carbon monoxide alarms are a separate purchase

Government guidance for landlords in England points to British Standards BS 5839-6 for smoke alarms and BS 50291 for carbon monoxide alarms, and those are the numbers worth quoting back when a quotation simply says alarms. A device sold cheaply with no clear standard marking is not a bargain; it is an unknown, and it is being asked to work once, years from now, on the worst night of your life.

Carbon monoxide alarms deserve their own thought because they are not fire detectors and they are not interchangeable with them. HSE describes carbon monoxide as a colourless, odourless, tasteless, poisonous gas produced by incomplete burning of carbon-based fuels, including gas, oil, wood and coal, and points out that it is only when the fuel does not burn properly that excess carbon monoxide is produced. A carbon monoxide alarm therefore protects against an appliance failing, not against a fire, which is why the rules place it in the room with the appliance.

It is also not a substitute for maintaining the appliance. An alarm is the last line, and the first line is having combustion appliances installed and serviced by someone competent to work on that fuel. In England, the amendments to Approved Document J are described by government as extending the provisions and guidance for carbon monoxide alarms, so when a new or replacement fixed combustion appliance is being installed, ask the installer directly what the current guidance requires for an alarm as part of that work.

Testing, cleaning and replacing alarms

  • Test every alarm with its own test button on a routine you will actually keep, and check that interlinked alarms all sound when one is tested.
  • Keep alarms clean and free of dust and cobwebs, and never paint one or cover it during decorating.
  • Treat a regular chirp as end of life or a failing battery rather than as background noise, and deal with it rather than removing the alarm.
  • Replace alarms at the end of their stated service life, since the sensors age whether or not the alarm has ever sounded.
  • Make sure every alarm is reachable for testing, particularly on landings and in stairwells with high ceilings.
  • Landlords in England should record the check made on the first day of a new tenancy, because the duty is to ensure the alarm is in proper working order on that day.
  • After any building work, check that alarms were not removed, disconnected or covered and then forgotten.

What to do when a carbon monoxide alarm sounds

Treat it as real, every time. Get everyone out into fresh air, do not go back in to investigate, and do not assume a false alarm because nobody feels unwell. The symptoms HSE lists are ordinary enough to be missed or mistaken for something else: headaches or dizziness, breathlessness, nausea, tiredness, pains in the chest or stomach, erratic behaviour, visual problems and loss of consciousness, and people asleep will not notice them at all.

If anyone is unwell, that is a call for emergency medical help, not a call to a tradesperson. Once people are safe, the appliance that caused it has to be found and dealt with by someone competent to work on that fuel before it goes back into use. HSE also lists warning signs of incomplete combustion worth knowing in advance: yellow or orange flames rather than blue on appliances that should burn blue, soot or yellow-brown staining around an appliance, pilot lights that frequently blow out, and increased condensation inside windows.

False alarms, chirping and the mistakes that make a system useless

  • A smoke alarm fitted in a kitchen instead of a heat alarm, which triggers on cooking until somebody takes the battery out.
  • An alarm sited too close to a wall or too near a bathroom door, where steam and dead air cause nuisance alarms.
  • Alarms that are not interlinked in a two or three storey house, so an alarm downstairs cannot wake anyone upstairs.
  • A chirping alarm silenced by removing the battery, which is how homes end up with alarms that are purely decorative.
  • Alarms past their service life left in place because they still respond to the test button.
  • A carbon monoxide alarm put in the hall rather than in the room containing the fuel-burning appliance.
  • Alarms painted over, covered during decorating, or knocked off during building work and never refitted.
  • A kitchen or utility room extension built without anyone revisiting whether the existing alarm coverage still matches the layout.

What drives the cost of having alarms fitted

Alarm work is priced on the number of positions and on how the alarms are linked, far more than on the devices. The difference between a battery retrofit and a mains-wired interlinked system across three storeys is mostly cable routes and making good.

  • How many alarms are needed, which follows the number of storeys, halls, landings and rooms with fuel-burning appliances.
  • Mains-wired and interlinked by cable, or sealed-battery and interlinked by radio.
  • Ceiling and wall construction, and whether cables can be run through a loft or under floors rather than chased into plaster.
  • Whether the work is being done alongside a rewire or refurbishment, when cable runs are cheap, or into a finished occupied house, when they are not.
  • Making good and redecoration, which is one of the most commonly excluded items on a quotation.
  • Ceiling height and access, particularly in stairwells and over landings.
  • Pre-2000 textured ceiling coatings, which have to be identified and handled appropriately before anyone drills.
  • Whether existing alarms are being replaced and removed, or added to.

Smoke & CO Detector Installation: frequently asked questions

How many smoke alarms does my home need?

It depends which nation you are in. England's rented-sector rule is one smoke alarm on each storey of the premises on which there is a room used wholly or partly as living accommodation. Scotland's standard is more prescriptive and applies to every home: one smoke alarm in the living room or the room you use most, one smoke alarm in every hallway and landing, and one heat alarm in the kitchen, all ceiling mounted and interlinked.

Do I need a carbon monoxide alarm if I only have a gas cooker?

Under the England regulations for rented homes, the gas cooker is the exception: regulation 4 requires a carbon monoxide alarm in any room used wholly or partly as living accommodation that contains a fixed combustion appliance other than a gas cooker. Scotland's guidance takes the same line, saying gas cookers and hobs do not need a carbon monoxide detector while a carbon-fuelled appliance like a boiler, open fire or wood burner does. A gas fire, boiler, stove or open fire therefore does require one.

I own my home in England. Do these rules apply to me?

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 place their duties on landlords of specified tenancies, so they do not impose the same duties on an owner-occupier. That is a statement about who the regulations bind, not about what is sensible: the coverage they describe is a reasonable minimum for any home, and building regulations still apply to work you have done. In Scotland the position is different again, because the standard applies to every home and meeting it is the property owner's responsibility.

Should alarms be mains-wired or battery?

Both routes are used and both can meet the relevant standard. Mains-wired interlinked alarms make most sense when cables can be run during a rewire, an extension or a refurbishment. Sealed long-life battery alarms interlinked by radio avoid chasing walls and lifting floors, which is why they dominate retrofits into finished homes. The feature that matters most in either case is interlinking, so that an alarm sounding in one part of the house is heard everywhere in it.

Where exactly should an alarm be positioned?

The Scottish Government's guidance gives usable figures: ceiling mounted and at least 300 mm from any wall, unless otherwise indicated by the manufacturer, or wall mounted at least 150 mm below the ceiling and higher than any door or window. Government guidance for landlords in England adds that smoke alarms should be fixed to the ceiling in a circulation space such as a hall or landing. The manufacturer's instructions for the specific alarm sit over the top of all of that.

What happens to a landlord who does not fit alarms?

In England the local housing authority serves a remedial notice, and under regulation 8 of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 it may then require a penalty charge, the amount of which must not exceed £5,000. Government guidance for landlords describes failure to comply with each remedial notice as leading to a fine of up to that amount. It is also worth noting the repair duty: an alarm reported as faulty on or after 1st October 2022 must be repaired or replaced as soon as reasonably practicable.

Sources

  1. Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 4 - duties of relevant landlord
  2. Smoke and Carbon Monoxide Alarm (England) Regulations 2015, regulation 8 - penalty charge
  3. GOV.UK: Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 - guidance for landlords and tenants
  4. Scottish Government: Fire and smoke alarms in Scottish homes
  5. Scottish Government: Fire and smoke alarms - what each home needs
  6. Scottish Government: Fire and smoke alarms - installation of alarms
  7. Housing (Scotland) Act 1987, section 86 - the tolerable standard
  8. Private Tenancies Act (Northern Ireland) 2022, section 8 - fire, smoke and carbon monoxide alarms
  9. GOV.UK: Approved Document J - combustion appliances and fuel storage systems
  10. HSE: Carbon monoxide - the gas, its symptoms and the signs of incomplete combustion

Written by the LokalMatch editorial team. Last reviewed 14 September 2026. How we write and check our guides

Find electricians by city

England

Show 173 cities

What affects the cost of smoke and CO detector

Prices depend on the details of your project. We only publish price ranges when they’re backed by real LokalMatch quote data or reliable sources. Until then, here’s what usually changes the price:

  • Type and amount of work, from a single fixture to a full rewire
  • Condition and age of the existing wiring
  • Panel and service capacity
  • Distance from the panel to the new circuit
  • Access through finished walls and ceilings
  • Permits and inspections

How to compare electricians before you hire

  • Hire a licensed electrician or electrical contractor for any wiring, panel or new circuit work.
  • Ask whether the work needs a permit and inspection, and make sure the electrician arranges it.
  • Get a written quote that lists fixtures, materials, patching of walls and ceilings, and permit costs.
  • For panel upgrades and EV chargers, ask them to check whether your electrical service can handle the added load.
  • Choose someone who explains what they found in plain language before starting.

Questions to ask electricians before you hire

  • Are you licensed for electrical work in my area?
  • Will you get the permit and arrange the inspection?
  • Can my current panel and service handle this work?
  • Will you need to open walls or ceilings, and who patches them afterwards?
  • Is the price fixed, or could it change once you see the existing wiring?
  • What warranty do you offer on your work?

When to call a pro for smoke and CO detector

  • Burning smells, scorch marks or warm outlets and switches: turn off the circuit at the panel if it's safe to do so and call an electrician.
  • Breakers that trip again and again
  • Flickering or dimming lights that aren't fixed by changing the bulb
  • Any sparking, buzzing or exposed wiring

Smoke and CO detector permits and local rules

Some smoke and CO detector work needs a permit or has to meet local bylaws. Rules vary by municipality, so ask your pro whether a permit is needed and who will apply for it — and check with your city or town if you’re unsure.

Permits and licensing

Ready to get smoke and CO detector quotes?

Tell us about your smoke and CO detector project.

Do you offer smoke and CO detector services?

Join LokalMatch to get matched with homeowners in the areas you serve.