Ventilation near you

Ventilation is the quiet system in a British home, and the one most often broken by good intentions. Older housing here was ventilated largely by accident, through draughts, open chimneys and loose windows, which is why Approved Document F observes that many existing dwellings are ventilated through infiltration rather than purposeful ventilation. Seal that leakiness up with new windows, loft insulation and draught-proofing, and the moisture a household produces every day has nowhere to go.

Tell us about your ventilation project and we’ll help you find local ventilation contractors who serve your area.

Free for homeowners · No obligation to hire

On this page

The work itself ranges from a single extract fan in a shower room to a full mechanical ventilation with heat recovery system in an airtight new build. In between sit the jobs most households actually need: a fan that meets its rate, background ventilators in the windows, a cooker hood that discharges outside, and internal doors undercut so air can move through the house at all.

The rules in England come from Part F of the Building Regulations, with Approved Document F Volume 1 covering dwellings; the current editions came into force on 15 June 2022. Part O now governs overheating in new residential buildings, and separate government guidance addresses damp and mould, an area where the law has tightened sharply for social landlords. Scotland and Northern Ireland set their own standards.

The three ventilation systems Approved Document F recognises for dwellings

Approved Document F sets out system-specific guidance for three approaches, and the choice depends heavily on how airtight the dwelling is. Getting this wrong is why some retrofitted homes feel stuffy and damp despite new fans.

  • Natural ventilation with background ventilators and intermittent extract fans: trickle ventilators supplying air to habitable rooms with fans boosting the wet rooms. Approved Document F marks this as guidance suitable only for less airtight dwellings.
  • Continuous mechanical extract ventilation: a fan or fans running continuously at a low rate with a high rate for when more extraction is needed, which the guidance treats as suitable for all dwellings, and which is also available as decentralised units replacing individual intermittent fans.
  • Mechanical ventilation with heat recovery: mechanical supply to every habitable room and extract from every wet room, with heat recovered from the outgoing air. Supply is distributed proportionately to the volume of each habitable room, and the system must be designed so moist air from wet rooms does not recirculate into habitable rooms.
  • With heat recovery, background ventilators should not be installed alongside it, to avoid unintended air pathways; where MVHR is added to an existing dwelling, existing background ventilators should be covered or sealed shut.
  • Purge ventilation sits across all three: a means of clearing high concentrations of pollutants and water vapour occasionally, for example fumes from painting, capable of at least four air changes per hour per room directly to outside.

The extract rates and whole-dwelling rates Part F actually requires

Extract ventilation to the outside should be provided in kitchens, utility rooms, bathrooms and sanitary accommodation, and it can be intermittent or continuous. For intermittent systems, Approved Document F Volume 1 sets minimum extract rates in litres per second: 30 for a kitchen where a cooker hood extracts to the outside, 60 for a kitchen with no cooker hood or where the hood does not extract outside, 30 for a utility room, 15 for a bathroom and 6 for sanitary accommodation, with the purge ventilation guidance available as an alternative for sanitary accommodation.

Continuous systems are specified differently, with a minimum high rate of 13 litres per second for a kitchen, 8 for a utility room, 8 for a bathroom and 6 for sanitary accommodation, and a continuous rate such that the sum of all extract in the dwelling is at least the whole dwelling ventilation rate.

That whole dwelling rate has two parts, both of which have to be met: a minimum of 0.3 litres per second for each square metre of internal floor area counting all storeys, and a minimum set by bedroom count, which runs 19 litres per second for one bedroom, 25 for two, 31 for three, 37 for four and 43 for five, adding 6 for each additional bedroom. A dwelling with only one habitable room uses 13 litres per second.

Background ventilators, trickle vents and replacement windows

Background ventilators, the small controllable openings usually built into the window head, are how supply air reaches habitable rooms in a naturally ventilated house. Approved Document F sizes them by equivalent area in square millimetres rather than free area, and expects that equivalent area to be marked where it is easy to see from inside the dwelling so building control can verify it.

Replacing windows is the moment this is most often lost, which is why Approved Document F addresses it directly. Where the existing windows have background ventilators, the replacements should include them too, no smaller than those in the original window and controllable either automatically or by the occupant. Where the old windows had none, the replacement is likely to increase the airtightness of the dwelling, and the ventilation provision must end up no worse than before the work.

The guidance gives concrete sizes for that case: background ventilators in the replacement windows with a minimum equivalent area of 8,000 square millimetres in habitable rooms, 8,000 in a kitchen and 4,000 in a bathroom with or without a toilet. Where the dwelling will have continuous mechanical extract ventilation instead, the figure is a minimum of 4,000 square millimetres in each habitable room for replacement windows outside wet rooms. These editions of Approved Document F came into force on 15 June 2022 in England.

Under-ventilation, condensation and mould

The signs of an under-ventilated home are consistent: windows streaming in the morning, a bathroom that stays damp for hours, musty smells in cupboards on outside walls, and black mould returning in the same corners after every clean. Government guidance describes condensation, the most common form of damp, as moisture generated inside the home cooling and condensing onto colder parts of the building.

The same guidance is blunt about cause and blame: it states that it is totally unreasonable to blame damp and mould in the home on lifestyle choices, and locates the fundamental cause in building deficiencies, inadequate ventilation, inadequate heating and/or poor energy efficiency. Cooking, washing and breathing produce moisture in every household; the question is whether the building can deal with it.

The health case for fixing it is serious. That guidance notes that the respiratory effects of damp and mould can cause serious illness and, in the most severe cases, death, and lists those most at risk, including people with pre-existing respiratory conditions or weakened immune systems, children, older people, pregnant women and those in fuel poverty. It recommends that kitchens have extractor fans or cooker hoods that are fully operational and sufficiently powered, and that bathrooms have ventilation systems such as extractor fans, suggesting humidity-controlled fans and fans linked to the light switch with an over-run.

Retrofit, notification and the rules across the UK

Approved Document F states that building work should not reduce the ventilation provision of a dwelling unless the provision afterwards still meets the minimum standards. For energy efficiency work it offers a simplified method: measures are counted as major or minor, from loft and cavity insulation to sealing a suspended floor or blocking a chimney, and the combination puts the job in Category A, B or C. Category A suggests no further ventilation is needed; Categories B and C indicate the provision has likely fallen below requirement and further ventilation should be added, by natural means, continuous mechanical extract or heat recovery.

Some work is lighter touch than people expect. Approved Document F notes that replacing an extractor fan or cooker hood using the existing cabling does not need to be notified to a building control body, while GOV.UK explains that you do not need to seek approval yourself if you use an installer registered with a competent person scheme. Where a wet room is added to an existing dwelling, extract must be provided along with a background ventilator of at least 5,000 square millimetres equivalent area, unless continuous extract or a single-room heat recovery ventilator is used.

Devolution matters here. Scotland's system under the Building (Scotland) Act 2003 runs on a building warrant before work begins and a completion certificate before occupation, with the domestic technical handbook covering ventilation in Section 3 and energy in Section 6. In Northern Ireland, the Building Regulations (Northern Ireland) 2012 deal with ventilation in Part K, so quoting English part letters to a Belfast building control officer will not get you far.

Winter condensation, summer overheating and Part O

Ventilation needs change with the season, and the winter instinct to shut everything is what starts most condensation problems. Background ventilators are designed to stay open in normal use, and government guidance on ventilating homes advises checking that trickle vents or grilles are open and not blocked, noting that opening windows and doors is the simplest way of improving ventilation for most people and that windows do not need to be open all the time to be effective. It also points to keeping rooms at least 18 degrees Celsius for older people and those with health conditions, which is why ventilation and heating have to be considered together rather than traded off.

Summer is now a regulated concern for new homes. Part O covers overheating mitigation, and Approved Document O applies to new residential buildings, working through limiting unwanted solar gains and removing excess heat, using passive means as far as reasonably practicable. It does not apply to existing homes, to retrofits, or to extensions and conservatories added to residential buildings after they are built. Where mechanical cooling is used in a new building, the designer has to demonstrate to the building control body that all practicable passive means have also been incorporated.

Keeping a ventilation system working, and hiring through LokalMatch

A ventilation system is only as good as its upkeep: vents left open and clear, filters changed on the manufacturer's schedule, grilles washed, and fans checked occasionally to confirm they still move air rather than merely make noise. The installer is required to give the owner sufficient information about the system and its maintenance requirements so it can be operated to provide adequate ventilation, and that written guidance is worth keeping with the property's paperwork.

When it is time to bring someone in, LokalMatch lets you describe the problem once, with the rooms affected, the age and type of the property and what has already been tried, and matched local professionals reach out to you. Pros pay to receive those requests, which is how LokalMatch makes its money. The service does not carry out ventilation work, does not set the price of any job, and does not vet, rank or recommend the pros who respond, so ask each one how they will measure the resulting air flow rates.

Ventilation: frequently asked questions

What extract rate does a bathroom fan need?

For an intermittent extract system, Approved Document F Volume 1 sets a minimum of 15 litres per second for a bathroom, 6 for sanitary accommodation, 30 for a utility room, 30 for a kitchen where a cooker hood extracts outside and 60 for a kitchen where it does not. Continuous systems use lower high rates, including 8 litres per second for a bathroom.

Do replacement windows have to include trickle vents?

Where the existing windows had background ventilators, the replacements should include them, no smaller than the originals and controllable. Where they did not, ventilation must be no worse than before, which Approved Document F demonstrates through minimum equivalent areas of 8,000 square millimetres in habitable rooms and kitchens and 4,000 in bathrooms. The current editions came into force on 15 June 2022 in England.

We insulated the house and now it feels damp. What changed?

Airtightness. Approved Document F notes many existing homes are ventilated by infiltration rather than purposeful ventilation, so insulation and draught-proofing can leave a dwelling under-ventilated. Its simplified method counts major and minor measures to categorise the impact, and Categories B and C call for added ventilation through natural means, continuous mechanical extract or heat recovery.

Should I close the trickle vents in winter to save heat?

They are meant to stay open in normal use. Government guidance advises checking that trickle vents and grilles are open and not blocked, and closing them is a common route to condensation and mould. Warmth and ventilation work together: the same guidance suggests keeping rooms at least 18 degrees Celsius for older people and those with health conditions.

Does Part O stop my home overheating?

Only if it is a new residential building. Approved Document O applies to new residential buildings, addressing overheating by limiting unwanted solar gains and removing excess heat through passive means as far as reasonably practicable. It does not apply to existing homes, retrofits, or extensions and conservatories added after a building is built.

My rented home has mould and the landlord blames how we live. Is that right?

Government guidance states it is totally unreasonable to blame damp and mould on lifestyle choices, placing the fundamental cause in building deficiencies, inadequate ventilation, inadequate heating and/or poor energy efficiency. For social housing, Awaab's Law took effect on 27 October 2025 for damp and mould, requiring significant hazards to be investigated within 10 working days.

Sources

  1. GOV.UK: Ventilation, Approved Document F
  2. Approved Document F, Volume 1: Dwellings, 2021 edition (PDF)
  3. GOV.UK: Overheating, Approved Document O
  4. GOV.UK: Approved Document O overheating, frequently asked questions
  5. GOV.UK: Understanding and addressing the health risks of damp and mould in the home
  6. GOV.UK: Awaab's Law, guidance for social landlords
  7. GOV.UK: Ventilation to reduce the spread of respiratory infections
  8. Scottish Government: Building standards technical handbooks
  9. The Building Regulations (Northern Ireland) 2012

Written by the LokalMatch editorial team. Last reviewed 14 September 2026. How we write and check our guides

Find ventilation contractors by city

England

Show 173 cities

What affects the cost of ventilation

Prices depend on the details of your project. We only publish price ranges when they’re backed by real LokalMatch quote data or reliable sources. Until then, here’s what usually changes the price:

  • Type of system and fuel source
  • Size and efficiency of the equipment
  • Condition of the existing ductwork and venting
  • Electrical or gas line changes
  • Access to the furnace room, attic or outdoor unit location
  • Removal and disposal of the old equipment
  • Emergency or after-hours service

How to compare ventilation contractors before you hire

  • Hire a technician who is licensed for heating, cooling and gas work in your area.
  • For a new system, ask for a load calculation for your home rather than a size based on the old unit.
  • Get written quotes that list the equipment, ductwork changes, removal of the old unit and any electrical work.
  • Ask how they handle service calls and repairs after installation, including in the middle of winter.
  • Compare the full scope of each quote, not only the equipment on it.

Questions to ask ventilation contractors before you hire

  • Are you licensed for this type of heating, cooling or gas work in my area?
  • How did you decide what size of system my home needs?
  • Does this installation need a permit, and will you take care of it?
  • What does the manufacturer's warranty cover, and what does your labour warranty cover?
  • Will you need to change the ductwork, venting or electrical to make this work?
  • Do you offer maintenance plans, and what do they include?
  • How quickly can you respond if the system stops working?

When to call a pro for ventilation

  • If you smell gas, leave the home and call your gas utility's emergency line from outside.
  • If a carbon monoxide alarm goes off, get everyone outside and call emergency services.
  • No heat in cold weather, or a furnace that keeps shutting off
  • Unusual noises, burning smells or a big jump in energy use

Ventilation permits and local rules

Some ventilation work needs a permit or has to meet local bylaws. Rules vary by municipality, so ask your pro whether a permit is needed and who will apply for it — and check with your city or town if you’re unsure.