Range Hood Installation near you

Installing a range hood is one of the few kitchen jobs where the appliance is the easy part. The hood itself hangs on a few screws. What decides whether it works is the duct behind it: where it goes, what it is made of, how many turns it takes, where it comes out of the building, and whether the kitchen can supply the air the fan is trying to pull. Those questions are governed by code in most of the country, and the answers are not negotiable.

Tell us about your range hood project and we’ll help you find local appliance installers who serve your area.

Free for homeowners · No obligation to hire

On this page

The reason the rules exist is air quality rather than smell. EPA and CPSC's joint guide to indoor air quality lists gas stoves among the household sources of carbon monoxide, nitrogen dioxide and particles, and its advice is direct: install and use exhaust fans over gas cooking stoves and ranges, keep the burners properly adjusted, and note that using a stove hood with a fan vented to the outdoors greatly reduces exposure to pollutants during cooking. A hood that filters the air and returns it to the room does not do that.

This guide covers the hood styles used in American kitchens, the model code requirements for discharge, duct material and termination, the mounting height a range dictates, the makeup air rule that catches powerful hoods in tight houses, the separate requirements that apply in a manufactured home, and what to check before the installer leaves.

Under-cabinet, wall chimney, island, insert and downdraft hoods

  • Under-cabinet hoods mount to the cabinet above the range and are the most common American installation, ducting up through the cabinet, back through the wall, or recirculating if no duct exists.
  • Wall chimney hoods take the place of the cabinet entirely, which usually means cabinetry work as well as ducting and is the moment to route the duct properly rather than reuse what is there.
  • Island hoods hang from the ceiling over a cooktop, carry the longest vertical runs and are the least forgiving of a cramped route through joists.
  • Inserts and liners sit inside a custom hood surround, so the blower, the duct and the surround all have to be planned together before the millwork is built.
  • Downdraft units pull across the cooking surface rather than over it and run their duct below the floor, which the code addresses separately in the duct material rules.
  • Over-the-range microwaves combine a microwave with a hood, and are frequently installed in recirculating mode by default even where a duct route exists.
  • Professional-style ranges usually call for a larger hood and a higher airflow, which is where the makeup air requirement starts to apply.

Ducted or recirculating: what the code allows and what each actually removes

The model residential code's default is unambiguous. Domestic cooking exhaust equipment must discharge to the outdoors through a duct, and that duct must have a smooth interior surface, must be airtight, must be equipped with a backdraft damper, and must be independent of all other exhaust systems. Ducts serving domestic cooking exhaust equipment must not terminate in an attic or crawl space, or in areas inside the building. A hood dumped into an attic is not a shortcut; it is a code violation that deposits grease and moisture into the roof structure.

There is an exception, and it is narrower than the marketing suggests. Where installed in accordance with the manufacturer's instructions, and where other ventilation is provided, listed and labeled ductless range hoods are not required to discharge to the outdoors. Jurisdictions amend the second half of that condition: Seattle, enforcing the Washington amendments, replaces the model text's general reference to mechanical or natural ventilation with a requirement for continuous local exhaust in an enclosed kitchen at a rate set in the code's own table. So whether a ductless hood is acceptable where you live depends on which version your jurisdiction has adopted, which is a question for the building department, not for the appliance store.

Regardless of what is permitted, be clear about what each type does. A recirculating hood passes air through a grease filter and usually a charcoal filter and returns it to the kitchen, which captures grease and reduces odour. It does not remove water vapour, and it does not remove the combustion products EPA's guidance is concerned with. If the cooking appliance burns gas, the ducted option is doing something the recirculating one cannot.

Duct material, routing and the exterior termination

The code names the materials. Ducts serving domestic cooking exhaust equipment must be constructed of galvanized steel, stainless steel or copper. The one exception is for downdraft systems, where schedule 40 PVC pipe and fittings are permitted under tightly drawn conditions: the duct installed under a concrete slab poured on grade, the underfloor trench completely backfilled with sand or gravel, the PVC extending not more than one inch above the indoor concrete floor surface and not more than one inch above grade outside, and all joints solvent cemented.

What that rules out is the flexible foil and plastic ducting that turns up behind a surprising number of installed hoods. It is not smooth, it is not airtight, it catches grease along every ridge, and it crushes when a cabinet is pushed back against it. If a quote does not say what the duct is made of, ask before the work starts rather than after the drywall closes.

  • Keep the run as short and as straight as the layout allows; every elbow costs airflow the fan has to make up.
  • Match the duct to the hood's specified diameter rather than reducing it to fit a joist bay, because a restriction anywhere sets the airflow for the whole system.
  • Seal the joints and support the duct so it cannot sag or separate above a ceiling where nobody will see it.
  • Terminate outdoors at a hood or roof cap with a damper that swings freely, and check it from outside with the fan running.
  • Screen or louvre the termination against birds and rodents, and keep it clear of windows, doors and air intakes.
  • A duct that passes through unconditioned space will collect condensation in a cold climate, so plan for insulation rather than discovering a drip at the hood.

Mounting height, clearances and the permit side of the job

Mounting height is set by the cooking appliance below, not by taste. The model fuel gas code requires a vertical clearance above the cooking top of not less than 30 inches to combustible material and metal cabinets, and permits 24 inches where one of two protections is present: the underside of the material or cabinet above is protected with insulating millboard covered with sheet metal of the specified thickness, or a metal ventilating hood of that sheet metal thickness is installed above the cooking top with a small clearance beneath the combustible material, the hood being at least as wide as the appliance and centred over it. The hood manufacturer's own instructions then set a range within those limits, and the code requires cooking appliances to be installed in accordance with the manufacturer's instructions in any case.

Width and depth matter as much as height, because a hood narrower than the cooking surface cannot capture what happens at the outer burners, and a shallow hood hung high over a deep range catches less again. This is worth settling on paper before the cabinetry is ordered.

Permits and trades vary by jurisdiction, and the divisions are not intuitive. Seattle's mechanical permit, for example, covers heating, venting and air conditioning equipment and kitchen hood exhaust systems, but explicitly does not cover gas lines, refrigeration, plumbing or sprinklers, each of which needs its own permit. The electrical connection for the hood is separate again. Ask your building department which permits a hood installation needs where you live, and ask the installer who is pulling them.

Makeup air: when a powerful hood starts pulling against the house

A hood is only an exhaust fan, and a well-sealed modern house does not give up air easily. The model code draws the line explicitly: where one or more gas, liquid or solid fuel-burning appliances that are neither direct-vent nor use a mechanical draft venting system are located within a dwelling unit's air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute must be provided with makeup air, mechanically or passively, at a rate approximately equal to the exhaust rate, with at least one damper meeting the code's requirements. The makeup air has to be discharged into the same room as the exhaust system, or into rooms or duct systems that communicate with it through permanent openings of at least the required area.

The fuel gas side of the code makes the same point from the appliance's direction: where exhaust fans, clothes dryers and kitchen ventilation systems interfere with the operation of appliances, makeup air must be provided. The failure this prevents is backdrafting, where a large hood depressurises the house enough to pull combustion products back down the vent of a water heater or furnace instead of letting them leave.

In practice this is the single most common reason a hood specification changes partway through a kitchen project. A professional-style hood over a professional-style range can easily exceed the threshold, and the makeup air system that then becomes necessary is a real piece of work with its own duct, damper and control. Raise it at the design stage rather than at the inspection.

Manufactured homes: the separate federal requirements that apply

A manufactured home is built to a federal standard rather than to a locally adopted building code, and HUD's Manufactured Home Construction and Safety Standards set their own kitchen ventilation requirements. The area in which cooking appliances are located must be ventilated either by a metal duct, which may be single wall, of not less than 12.5 square inches in cross-sectional area with a minimum dimension of two inches, located above the appliance and terminating outside the home, or by listed mechanical ventilating equipment discharging outside the home and installed in accordance with the terms of its listing and the manufacturer's instructions. Either way, the gravity or mechanical ventilation must be within a horizontal distance of not more than ten feet from the vertical front of the appliance.

Two further requirements come with it. Mechanical ventilation that exhausts directly to the outside atmosphere from the living space must be equipped with an automatic or manual damper, and its controls must allow it to be operated separately without energising other energy-consuming devices. Separately, the standards require ranges to have a vertical clearance above the cooking top of not less than 24 inches.

If your home is a manufactured home, say so when you get quotes. An installer working from a site-built playbook will not necessarily know that the ventilation requirement, the duct sizing and the clearance above the cooking top come from a different rulebook.

Filters, dampers and the checks that keep a hood working

  • Wash the metal grease filters on the manufacturer's schedule; a loaded filter is the most common reason a hood that used to work appears to have weakened.
  • Replace charcoal filters on a recirculating hood on schedule, because unlike a grease filter they cannot be cleaned and simply stop working quietly.
  • Check the backdraft damper at the hood and the flap at the exterior termination once a year, since a damper stuck shut kills the airflow and a damper stuck open lets outside air and insects in.
  • Look at the exterior cap from outside with the fan running, which is the only way to confirm the system is actually discharging.
  • Have the duct cleaned periodically if the kitchen sees heavy frying, because grease accumulates along the run and not only at the filter.
  • Run the hood on a lower speed for the whole cooking session rather than on boost for two minutes at the end, which captures far more and is quieter.
  • Turn the hood on before lighting a gas burner, which is the habit that makes the difference EPA's guidance describes.

Before the installer leaves: what to inspect and what to keep

Ask to see the duct route before anything is closed up, and photograph it. Once drywall or cabinetry goes back, the difference between a rigid metal duct running to an exterior cap and a length of foil flex terminating in the attic is invisible, and it is the single most consequential detail in the job.

Run the hood on every speed with the kitchen door closed, watch the exterior damper open, and check that lights, fan speeds and any timer work as described. If there is a fuel-burning water heater or furnace inside the same air barrier, watch for any sign of its draft reversing when the hood runs at full speed, and raise it immediately if you see one.

Keep the model and serial number, the installation instructions and the invoice together, and check the model against CPSC's recall web service at SaferProducts.gov, which returns recalls by product type with the hazard and the remedy. Get the warranty on the installation, as distinct from the manufacturer's warranty on the appliance, written on the invoice rather than described at the door.

Range Hood Installation: frequently asked questions

Can a range hood be vented into the attic?

No. The model residential code requires domestic cooking exhaust equipment to discharge to the outdoors through a duct, and states that ducts serving that equipment must not terminate in an attic or crawl space or in areas inside the building. A hood discharging into an attic deposits grease and moisture into the roof structure, which is why the prohibition is written the way it is. If an existing hood in your house terminates that way, treat it as work to be corrected rather than as an installation choice.

Is a ductless range hood ever acceptable?

Sometimes, under a narrow exception. The model code permits listed and labeled ductless range hoods, installed in accordance with the manufacturer's instructions, where other ventilation is provided. Jurisdictions amend the second condition: Seattle, under the Washington amendments, requires continuous local exhaust in an enclosed kitchen at a rate set in the code's table instead of the model text's general reference to mechanical or natural ventilation. Ask your building department which version applies. Be clear about the trade-off too: a recirculating hood filters grease and odour but does not remove moisture or combustion products.

What should a range hood duct be made of?

The code requires ducts serving domestic cooking exhaust equipment to be constructed of galvanized steel, stainless steel or copper, with a smooth interior, airtight construction, a backdraft damper and independence from all other exhaust systems. The one exception covers downdraft systems, where schedule 40 PVC is permitted under specific conditions involving a duct run under a slab poured on grade in a backfilled trench. Flexible foil ducting meets none of the general requirements and should not be used.

How high above the stove should the hood go?

The model fuel gas code requires a vertical clearance above the cooking top of not less than 30 inches to combustible material and metal cabinets, with 24 inches permitted where the underside above is protected with insulating millboard covered with sheet metal, or where a metal ventilating hood of the specified thickness at least as wide as the appliance is installed above the cooking top. Within those limits, the hood manufacturer's instructions set the intended height, and the code requires installation in accordance with them. In a manufactured home, the federal standards require not less than 24 inches above the cooking top of a range.

Why is my installer talking about makeup air?

Because of a specific code requirement. Where a dwelling unit's air barrier contains one or more gas, liquid or solid fuel-burning appliances that are neither direct-vent nor use a mechanical draft venting system, any exhaust system capable of exhausting more than 400 cubic feet per minute must be provided with makeup air at approximately the same rate, with a compliant damper, and that air has to be delivered to the same room as the exhaust or a space connected to it by permanent openings. Without it, a large hood can depressurise the house enough to pull combustion products back down another appliance's vent.

How does LokalMatch work for range hood installation?

You describe the job once, including the hood style, whether it will be ducted or recirculating, what the range below it is, and whether the house is site-built or a manufactured home, and installers working in your area contact you directly. They pay LokalMatch for the requests; posting one is free. LokalMatch does not install hoods, does not set or negotiate prices, and does not vet, rank or recommend anyone, so confirming permits and the licences your jurisdiction requires remains your part. This guide is general information rather than legal or code advice, and your local adoption of the code governs.

Sources

  1. 2021 Seattle Residential Code, Chapter 15 Exhaust Systems (Section M1503, domestic cooking exhaust)
  2. 2021 Seattle Residential Code, Chapter 24 Fuel Gas (G2407 combustion air, G2447 cooking appliances)
  3. 24 CFR 3280.710, venting, ventilation and combustion air in manufactured homes, via govinfo
  4. 24 CFR 3280.709, installation of appliances in manufactured homes, via govinfo
  5. EPA and CPSC: The Inside Story, A Guide to Indoor Air Quality
  6. Seattle SDCI: Mechanical Permit
  7. CPSC recall web service (SaferProducts.gov)

Written by the LokalMatch editorial team. Last reviewed September 21, 2026. How we write and check our guides

Find appliance installers by city

California

Show 186 cities

Florida

Show 82 cities

Texas

Show 79 cities

What affects the cost of range hood

Prices depend on the details of your project. We only publish price ranges when they’re backed by real LokalMatch quote data or reliable sources. Until then, here’s what usually changes the price:

  • Type and make of appliance
  • The part that has failed and whether it's in stock
  • Diagnostic or service call fee
  • Built-in or hard-to-reach installation
  • Gas, water or venting connections
  • Same-day or after-hours service

How to compare appliance installers before you hire

  • Choose a technician who services your type and make of appliance, and ask whether they carry common parts.
  • Ask what the diagnostic or service call fee is and whether it's applied to the repair.
  • For gas stoves, dryers or other gas appliances, use a technician licensed for gas work in your area.
  • Ask for the repair estimate before any work starts, so you can decide whether it's worth repairing.
  • Check what the warranty covers on parts and labour after the repair.

Questions to ask appliance installers before you hire

  • Do you service this type and make of appliance?
  • What is your diagnostic or service call fee, and is it credited toward the repair?
  • Is it worth repairing, given the appliance's age and condition?
  • Will you need to order parts, and how long will that take?
  • Are you licensed for gas appliance work in my area?
  • What warranty do you give on parts and labour?

When to call a pro for range hood

  • If you smell gas near a stove or dryer, leave the home and call your gas utility's emergency line from outside.
  • An appliance that sparks, smells like burning or trips the breaker: unplug it only if it's safe to do so and call a technician.
  • A washer or dishwasher that leaks onto the floor

Range hood permits and local rules

Some range hood work needs a permit or has to meet local bylaws. Rules vary by municipality, so ask your pro whether a permit is needed and who will apply for it — and check with your city or town if you’re unsure.

Permits and licensing